METREG ELECTRONIC TURBINE METERS MQME (QUANTOMETER)
METREG  ELECTRONIC TURBINE METERS MQME  (QUANTOMETER) TURBINE METER MEDENUS GAS TRAIN PRODUCT GAS PRODUCT Selangor, Malaysia, Kuala Lumpur (KL), Puchong Supplier, Supply, Supplies, Services | LSA Energy Resources Sdn Bhd
Download Files
MT_MQMe_2_Seiten_EN_2016_web_(1).pdf (399.66 KB)

The MQMe quantometer is based on the principle of a turbine flow meter with an integrated electronic index head. The MQM is designed for flow and volume measurement for natural gas, nitrogen, air (and other gases on request) in non-custody transfer and process applications. The MQM is available in sizes from DN 25 (1´´) to DN 150 (6´´) with a volume flow rate up to 1600 m3/h depending on meter size. The meter housing is made of high strength aluminum. Itis designed as a sandwich construction (installed between two flanges). A volume correction function (AGA NX-19) can be optionally integrated in the electronic index head. Several communication options are available for data transmission: RS 485, M-Bus, Modbus, HF and LF signal as well as a 4 to 20 mA output. On a standard basis the MQMe meter is battery powered with a calculated battery life time of 5 years under standard conditions. 

Characteristics

  • several options to transmit the measured an calculated data to a digital control system (DCS) or SCADA
  • equipped with alternatively RS 485 or M-Bus interface and one high frequency (HF) as well as one low frequency (LF) pulser
  • if an external power supply is connected to the MQME one 4 to 20 mA configurable signal is available
  • the rotation of the rotor can be scannes additionally with one external high frequency (HF) sensor
  • the HF-sensor signal allows the determination of the actual gas flow in high-resolution and can be transmit to any digital control system (DCS) or SCADA for flow control purposes
  • integrated electronic volume corrector

Options

  • WFactory calibration measuring range 1:20
  • integrated volume corrector (incl. pressure & temperature sensors)
  • analog output (4-20 mA, 24 VDC needed)
  • RS485 (M-bus not possible)
  • M-Bus (RS485 not possible)
  • additional HF sensor (external power supply needed)
  • Oil pump
  • 1x thermowell
  • Test certificate 3.1 with detailed materials list
Sizes: 1' (DN25) to 6' (DN150)
Connections:  
Materials: Meter body anodized aluminium / Meter head made of polymer material or aluminium (optional)
Flow Rates: 16 to 1600 m³/h
Medium: Gas
Pressure Class: PN10/PN16 or ANSI Class 150
Temperature:  
Approvals: PED and ATEX (zone 1)
Notes: (a) Horizontal or vertical mounting position (b) Maintenance free based on permanent lubrication (c) Protection class IP65